Skip to content

HVAC Filters

Category code: hvac-filters · SKUs: 14 · Status: catalog-confirmed

SKU Description Efficiency Data status
AIRY-FB-PANEL FB panel filter for HVAC pre-filtration, catalogued in the HVAC category with a cardboard or metal frame and synthetic-fiber media. The source confirms the frame options and media but the parameters here are reference-grade, not source-confirmed. Panel pre-filters capture coarse dust to protect downstream stages, and the frame choice follows the duty (cardboard for disposable, metal for washable). From a sourcing perspective, buyers should verify the grade and face size, and request pressure-drop and dust-holding data for energy-cost comparison. G4 catalog-confirmed
AIRY-PRE-PANEL Pre-panel filter for HVAC pre-filtration stages, with synthetic-fiber media. The source confirms the synthetic media but dimension, media and grade are recorded as reference figures A pre-stage protects the downstream media and trades low resistance for high capacity. Buyers should verify the grade and face size against the AHU, and request pressure-drop and dust-holding data for energy-cost comparison before ordering. G4 catalog-confirmed
AIRY-PLEATED-PRE Pleated pre-filter for HVAC systems, catalogued in the HVAC category with synthetic-fiber media. The source confirms the synthetic media and pleated construction but these fields are carried as reference values rather than a verified spec. The pleated form adds media area for lower pressure drop in pre-filtration. From a sourcing perspective, buyers should verify the grade and face size, and request pressure-drop and dust-holding data for energy-cost comparison before ordering. G4 catalog-confirmed
AIRY-CARDBOARD-PRE Cardboard-paper-frame pre-filter for HVAC, with synthetic media. The catalogue confirms the cardboard/paper frame and synthetic media but the spec figures are reference, not catalogue-verified. The cardboard frame is a disposable, low-cost pre-stage option where the downstream media is protected. From a sourcing view, verify the grade and face size, and request pressure-drop and dust-holding data to compare energy cost. Verify the reference on the spec sheet before ordering. G4 catalog-confirmed
KLC-HT-SEPARATOR High-temperature separator filter rated 260-350 °C, catalogued in the HVAC category with a metal frame and synthetic media. The source publishes the 260-350 °C temperature range and the metal frame but no grade, face size, airflow or pressure-drop figure. The separator construction and high heat resistance suit industrial high-temperature ventilation. From a sourcing perspective, buyers should confirm the exact operating temperature and the face size, and request pressure-drop data before ordering. — catalog-confirmed
KLC-MED-VBANK Medium V-bank filter, catalogued in the HVAC category with a metal or plastic frame and synthetic media. The source confirms the V-bank construction and frame options but publishes no grade, face size, airflow or pressure-drop figure. V-bank rigid filters deliver high airflow at low pressure drop for the main AHU stage. Our advice: verify the grade and face dimensions, and request initial/final pressure-drop and dust-holding data for energy-cost comparison before bulk ordering. F7 / F8 catalog-confirmed
KLC-MERV8 MERV 8 pleated filter, catalogued in the HVAC category with synthetic media. The source confirms the MERV 8 grade and synthetic media but publishes no face size, airflow or pressure-drop figure. MERV 8 is a mid-grade general-ventilation level. From a sourcing perspective, buyers should verify the face size and frame construction, and request pressure-drop and dust-holding data for energy-cost comparison before ordering. MERV 8 catalog-confirmed
KLC-G3-HT-PRIMARY G3 high-heat-resistance pleated primary filter, catalogued in the HVAC category with synthetic media. The source confirms the G3 grade, the pleated construction and the high-heat-resistance description but publishes no temperature figure, face size, airflow or pressure-drop figure. As a G3 primary stage, it captures coarse dust and protects downstream media. Our advice: verify the exact temperature requirement and the face size, and request pressure-drop data before bulk ordering. G3 catalog-confirmed
KLC-G1-G4-PANEL Washable G1/G2/G3/G4 synthetic-fiber panel filter, catalogued in the HVAC category. The source confirms the G1-G4 grade range and the washable synthetic construction but publishes no face size, airflow or pressure-drop figure. The washable panel form suits reusable pre-filtration where the downstream stage is protected. From a sourcing perspective, buyers should verify the exact grade and face size, and request pressure-drop and dust-holding data for energy-cost comparison. G1/G2/G3/G4 catalog-confirmed
YT-COARSE-G1-G4 Coarse ventilation filter graded G1-G4 (ISO 16890), catalogued in the HVAC category with synthetic media. The source confirms the G1-G4 grade range and the ISO 16890 reference but publishes no face size, airflow or pressure-drop figure. The coarse stage captures large particles and protects downstream media. Our advice: verify the exact grade and face size, and request pressure-drop and dust-holding data for energy-cost comparison before bulk ordering. G1-G4 catalog-confirmed
YT-MEDIUM-M5-M6 Medium ventilation filter graded M5/M6, catalogued in the HVAC category with synthetic media. The source confirms the M5/M6 grade range but publishes no face size, airflow or pressure-drop figure. The medium stage removes finer particulate behind the pre-filter. From a sourcing perspective, buyers should verify the exact grade and face size, and request pressure-drop and dust-holding data for energy-cost comparison before ordering. M5/M6 catalog-confirmed
YT-FINE-F7-F9 Fine ventilation filter graded F7/F8/F9, catalogued in the HVAC category with synthetic media. The source confirms the F7-F9 grade range but publishes no face size, airflow or pressure-drop figure. The fine stage handles fine particulate for higher-cleanliness HVAC duty. Our advice: verify the exact grade and face size, and request pressure-drop and dust-holding data for energy-cost comparison before bulk ordering. F7/F8/F9 catalog-confirmed
EAWAY-FLAT-F5 Metal-frame flat pre-air filter graded F5 with replaceable media, catalogued in the HVAC category. The source confirms the F5 grade, the metal frame and the replaceable media but publishes no face size, airflow or pressure-drop figure. The metal frame supports replaceable media for a reusable pre-stage. From a sourcing perspective, buyers should verify the face size and request pressure-drop and dust-holding data for energy-cost comparison before ordering. F5 catalog-confirmed
EAWAY-SUS-G4 SUS (stainless-steel) frame washable pleated air filter graded G4, catalogued in the HVAC category. The source confirms the G4 grade, the stainless-steel frame and the washable pleated construction but publishes no face size, airflow or pressure-drop figure. The stainless frame suits washable, corrosion-resistant pre-filtration. Our advice: verify the face size and request pressure-drop and dust-holding data for energy-cost comparison before bulk ordering. G4 catalog-confirmed